<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Server Room Cooling &#124; Spot Coolers &#124; ServerCOOL.com</title>
	<atom:link href="http://www.servercool.com/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.servercool.com</link>
	<description></description>
	<lastBuildDate>Tue, 18 Oct 2011 17:19:16 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.2.1</generator>
		<item>
		<title>Server Room Cooling (in the Winter)</title>
		<link>http://www.servercool.com/blog/server-room-cooling/</link>
		<comments>http://www.servercool.com/blog/server-room-cooling/#comments</comments>
		<pubDate>Tue, 18 Oct 2011 17:13:25 +0000</pubDate>
		<dc:creator>Bruce</dc:creator>
				<category><![CDATA[Blog]]></category>
		<category><![CDATA[Server Room Cooling]]></category>

		<guid isPermaLink="false">http://www.servercool.com/?p=1178</guid>
		<description><![CDATA[We just got our first good taste of cooler weather in Dallas this morning, where I actually felt the need to put on a long sleeved shirt. That tells me that the office buildings will soon be turning up the heat, which may wreck havoc on your server room cooling. There are a few things [...]]]></description>
			<content:encoded><![CDATA[<p><img class="size-full wp-image-39  alignright" style="float: right; padding-left: 10px;" title="Office Pro 36 - Air Cooled Portable Air Conditioner" src="http://www.servercool.com/wp-content/uploads/2009/01/op36_lg1.jpg" alt="Office Pro 36 - Air Cooled Portable Air Conditioner" width="200" height="290" /></p>
<p>We just got our first good taste of cooler weather in Dallas this morning, where I actually felt the need to put on a long sleeved shirt. That tells me that the office buildings will soon be turning up the heat, which may wreck havoc on your server room cooling.</p>
<p>There are a few things you can do to make sure that your server room doesn&#8217;t get over heated when the building turns up the heat this winter.</p>
<ol>
<li>Close off vents to prevent warm air from entering the room from the building&#8217;s central AC system.</li>
<li>Keep doors closed that connect to other heated rooms.</li>
<li>Check the exhaust ducts on your spot cooler to be sure the air flow is not obstructed going into the ceiling.</li>
<li>If you added additional heat generating equipment to your server room, be sure the installed unit is large enough to meet your needs.</li>
</ol>
<p>Now would also be a good time to clean the air filters on your portable AC unit, and clean your condensate pump if needed.</p>
<p>Supplemental spot cooling units may be needed if you are not able to maintain the desired temperature in your server room, so now is the time to start preparing for winter.</p>
<p>&nbsp;</p>
<div id="wp_thumbie" style= "border: 0pt none ; margin: 0pt; padding: 0pt; clear: both;"><div id="wp_thumbie_rl1"><h3>Related Products:</h3></div><ul class="wp_thumbie_ul_list" style="list-style-type: none; clear:both; height:190px"><li id="wp_thumbie_li" style="height:4px; width:190px; float:left; border:none"><div id="wp_thumbie_image"><a href="http://www.servercool.com/blog/condensate-pumps/how-to-clean-a-condensate-pump-for-spot-coolers/" target="_top"><img id="wp_thumbie_thumb" src="http://www.servercool.com/wp-content/plugins/wp-thumbie/timthumb.php?src=/wp-content/uploads/2011/09/how-to-clean-a-condensate-pump1.jpg&w=200&h=300&zc=1"/></a></div><div id="wp_thumbie_title"><a href="http://www.servercool.com/blog/condensate-pumps/how-to-clean-a-condensate-pump-for-spot-coolers/" target="_top">How to Clean a Condensate Pump - for Spot Coolers</a></div><p id="description"></p></li><li id="wp_thumbie_li" style="height:4px; width:190px; float:left; border:none"><div id="wp_thumbie_image"><a href="http://www.servercool.com/blog/spot-coolers/spot-cooling/" target="_top"><img id="wp_thumbie_thumb" src="http://www.servercool.com/wp-content/plugins/wp-thumbie/timthumb.php?src=/wp-content/uploads/2011/09/classic-plus-26.jpg&w=200&h=300&zc=1"/></a></div><div id="wp_thumbie_title"><a href="http://www.servercool.com/blog/spot-coolers/spot-cooling/" target="_top">Spot Cooling</a></div><p id="description"></p></li><li id="wp_thumbie_li" style="height:4px; width:190px; float:left; border:none"><div id="wp_thumbie_image"><a href="http://www.servercool.com/uncategorized/1020/" target="_top"><img id="wp_thumbie_thumb" src="http://www.servercool.com/wp-content/plugins/wp-thumbie/timthumb.php?src=/wp-content/plugins/wp-thumbie/images/default.png&w=200&h=300&zc=1"/></a></div><div id="wp_thumbie_title"><a href="http://www.servercool.com/uncategorized/1020/" target="_top"></a></div><p id="description"></p></li></ul><div id="wp_thumbie_rl2"><small>By </small><a href="http://www.blogsdna.com"><small>Blogsdna</small></a></div></div><div class="clear"></div>]]></content:encoded>
			<wfw:commentRss>http://www.servercool.com/blog/server-room-cooling/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Spot Cooling</title>
		<link>http://www.servercool.com/blog/spot-coolers/spot-cooling/</link>
		<comments>http://www.servercool.com/blog/spot-coolers/spot-cooling/#comments</comments>
		<pubDate>Mon, 12 Sep 2011 20:26:04 +0000</pubDate>
		<dc:creator>Bruce</dc:creator>
				<category><![CDATA[Spot Coolers]]></category>
		<category><![CDATA[spot coolers]]></category>
		<category><![CDATA[spot cooling]]></category>
		<category><![CDATA[spot cooling systems]]></category>

		<guid isPermaLink="false">http://www.servercool.com/?p=1154</guid>
		<description><![CDATA[Spot cooling for server rooms is a great way to combat hot spots or get supplemental cooling for your data center. With this summer being one of the hottest in Texas history, keeping company server room air conditioning at optimum temperatures is not an easy task. ServerCOOL provides MovinCool and AirPac portable AC units that [...]]]></description>
			<content:encoded><![CDATA[<p><a title="MovinCool Spot Coolers" href="http://www.servercool.com/spot-cooler/movincool-spot-coolers/"><img class="alignright size-full wp-image-1157" style="float: right; padding-left: 10px;" title="Spot Cooling - Spot Cooling Systems - Spot Coolers" src="http://www.servercool.com/wp-content/uploads/2011/09/classic-plus-26.jpg" alt="Spot Cooling - Spot Cooling Systems - Spot Coolers" width="215" height="360" />Spot cooling</a> for server rooms is a great way to combat hot spots or get supplemental cooling for your data center.<em></em></p>
<p>With this summer being one of the hottest in Texas history, keeping company server room air conditioning at optimum temperatures is not an easy task. ServerCOOL provides MovinCool and AirPac portable AC units that put the chill back into server room cooling.</p>
<p>ServerCOOL.com is excited to announce the launch of a new website promoting the sales and rentals of the MovinCool and AirPac brands of <a title="AirPac Portable Air Conditioner" href="http://www.servercool.com/spot-cooler/airpac-portable-air-conditioner/">portable AC units</a> and spot coolers for server room cooling. Customers can find <a title="Portable AC Rentals – Spot Cooler Rentals – Emergency AC Rentals" href="http://www.servercool.com/portable-ac-rentals-spot-cooler-rentals-emergency-ac-rentals/">portable AC rentals</a>, new portable ac units and portable air conditioning specifications.</p>
<p>The majority of our emergency response calls involve the failure of air conditioning equipment associated with critical temperature computer and server rooms. With this summer being one of the hottest in Texas history, keeping company server rooms at optimum temperatures is not an easy task. Servers and computers that run your network are all designed to function in a very specific temperature range, so even the smallest fluctuation can mean disaster if you do not have a good backup plan. This is where ServerCOOL comes into the picture.<span id="more-1154"></span></p>
<p>If a company’s computer server crashes, millions of dollars can be lost. The servers can be replaced, but the possible data loss can ruin a company. One of the main causes of server failure is due to overheating, so keeping a server room at the optimum temperature is crucial for peak performance. Part of every company’s disaster recovery plan should include a plan for emergency cooling systems in the event of a shutdown to facility air conditioning. Having several portable AC systems and spot coolers on hand for backup purposes would alleviate some of the problem.</p>
<p>The majority of our emergency response calls involve the failure of air conditioning equipment associated with critical temperature computer and server rooms.. When that happens, getting the server room back to its optimum temperature becomes a top priority for the facility manager, network manager and their <a title="Portable AC Company" href="http://www.servercool.com/">portable AC company</a>. This usually involves strategically placing portable AC units or <a title="Office Pro 24 – 24000 BTU" href="http://www.servercool.com/spot-cooler/movincool-spot-coolers/office-pro-24-24000-btu/">spot coolers</a> into the overheated rooms to remove heat and bring the temperature down as quickly as possible.</p>
<p>ServerCOOL offers <a title="PAC120 – 120,000 BTU" href="http://www.servercool.com/spot-cooler/airpac-portable-air-conditioner/pac120-120000-btu/">10 ton portable air conditioners</a> that can be rolled into place in minutes and will fit through a 32 inch doorway. This is a major feature not found in most portable AC systems of this size. Having the ability to place a portable cooler that produces 120,000 BTU’s of cold air into a server room can cool a server room down in minutes, which in most cases, saves the day.</p>
<p>ServerCOOL.com has also just implemented a new “live chat” system on their website to assist customers with portable AC sizing and application questions. We aim to give our customers a quick response. When their air conditioning goes down, customers need emergency cooling now, so having a system in place that allows them to chat with an expert speeds up the process of getting their server room back to its optimum temperature.</p>
<div id="wp_thumbie" style= "border: 0pt none ; margin: 0pt; padding: 0pt; clear: both;"><div id="wp_thumbie_rl1"><h3>Related Products:</h3></div><ul class="wp_thumbie_ul_list" style="list-style-type: none; clear:both; height:190px"><li id="wp_thumbie_li" style="height:4px; width:190px; float:left; border:none"><div id="wp_thumbie_image"><a href="http://www.servercool.com/uncategorized/1020/" target="_top"><img id="wp_thumbie_thumb" src="http://www.servercool.com/wp-content/plugins/wp-thumbie/timthumb.php?src=/wp-content/plugins/wp-thumbie/images/default.png&w=200&h=300&zc=1"/></a></div><div id="wp_thumbie_title"><a href="http://www.servercool.com/uncategorized/1020/" target="_top"></a></div><p id="description"></p></li><li id="wp_thumbie_li" style="height:4px; width:190px; float:left; border:none"><div id="wp_thumbie_image"><a href="http://www.servercool.com/spot-cooler-sizing/" target="_top"><img id="wp_thumbie_thumb" src="http://www.servercool.com/wp-content/plugins/wp-thumbie/timthumb.php?src=/wp-content/uploads/2011/08/movincool-spot-cooler-sizing.jpg&w=200&h=300&zc=1"/></a></div><div id="wp_thumbie_title"><a href="http://www.servercool.com/spot-cooler-sizing/" target="_top">Spot Cooler Sizing</a></div><p id="description"></p></li><li id="wp_thumbie_li" style="height:4px; width:190px; float:left; border:none"><div id="wp_thumbie_image"><a href="http://www.servercool.com/portable-ac-rentals-spot-cooler-rentals-emergency-ac-rentals/" target="_top"><img id="wp_thumbie_thumb" src="http://www.servercool.com/wp-content/plugins/wp-thumbie/timthumb.php?src=/wp-content/uploads/2011/07/map3.jpg&w=200&h=300&zc=1"/></a></div><div id="wp_thumbie_title"><a href="http://www.servercool.com/portable-ac-rentals-spot-cooler-rentals-emergency-ac-rentals/" target="_top">Portable AC Rentals - Spot Cooler Rentals - Emergency AC Rentals</a></div><p id="description"></p></li></ul><div id="wp_thumbie_rl2"><small>By </small><a href="http://www.blogsdna.com"><small>Blogsdna</small></a></div></div><div class="clear"></div>]]></content:encoded>
			<wfw:commentRss>http://www.servercool.com/blog/spot-coolers/spot-cooling/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>How to Clean a Condensate Pump &#8211; for Spot Coolers</title>
		<link>http://www.servercool.com/blog/condensate-pumps/how-to-clean-a-condensate-pump-for-spot-coolers/</link>
		<comments>http://www.servercool.com/blog/condensate-pumps/how-to-clean-a-condensate-pump-for-spot-coolers/#comments</comments>
		<pubDate>Thu, 08 Sep 2011 20:52:46 +0000</pubDate>
		<dc:creator>Bruce</dc:creator>
				<category><![CDATA[Condensate Pumps]]></category>
		<category><![CDATA[cleaning condensate pumps]]></category>
		<category><![CDATA[condensate pump]]></category>
		<category><![CDATA[condensate pumps]]></category>

		<guid isPermaLink="false">http://www.servercool.com/?p=1141</guid>
		<description><![CDATA[Ever wonder what&#8217;s inside your condensate pump? I&#8217;ll bet you weren&#8217;t thinking it was this kind of crud. This is an actual condensate pump we got back from a customer that was connected to a MovinCool Office Pro 12. I&#8217;m not really sure how old this pump is, or how long it has been on [...]]]></description>
			<content:encoded><![CDATA[<h3><img class="alignright size-full wp-image-1144" style="float: right; padding-left: 10px;" title="How to Clean a Condensate Pump" src="http://www.servercool.com/wp-content/uploads/2011/09/how-to-clean-a-condensate-pump1.jpg" alt="How to Clean a Condensate Pump" width="430" height="323" />Ever wonder what&#8217;s inside your condensate pump?</h3>
<p>I&#8217;ll bet you weren&#8217;t thinking it was this kind of crud. This is an actual condensate pump we got back from a customer that was connected to a <a title="Office Pro 12 – 12000 BTU" href="http://www.servercool.com/spot-cooler/movincool-spot-coolers/office-pro-12-12000-btu/">MovinCool Office Pro 12</a>. I&#8217;m not really sure how old this pump is, or how long it has been on that particular unit, but I&#8217;m willing to bet that this one was NEVER cleaned. And as you can figure, the unit stopped running because the pump quit working.</p>
<p>We quickly pulled this pump out and replaced it with a brand new pump, as this one has pretty much seen it&#8217;s better days. Customer is happy!<span id="more-1141"></span></p>
<h3>How to Clean a Condensate Pump &#8211; for Spot Coolers</h3>
<p>Cleaning a condensate pump on your <a title="Classic Plus 14" href="http://www.servercool.com/spot-cooler/movincool-spot-coolers/classic-plus-14/">portable AC unit</a> or spot cooler should be done at least once a year, but probably every six months just to be on the safe side. Below are the steps to keeping your condensate pump clean.</p>
<ol>
<li>Turn the power off on your spot cooler, then unplug the unit.</li>
<li>Remove the pump from the bottom of the unit. There should be one or two screws holding the pump to the condensate tank housing. Remove the pump and drain all of the water from the pump and housing.</li>
<li>Thoroughly wash the pump and tank housing with warm soapy water, including the float.</li>
<li>Make a solution of 1/4 cup bleach to 1 gallon of warm water. Pour the solution into the pump and continue until you have run the whole gallon through the pump and the lines.</li>
<li>Repeat this process one more time, using clean water without the bleach.</li>
<li>Reassemble the pump to the housing and install into your spot cooler.</li>
</ol>
<p>Cleaning your condensate pump is easy, and takes very little time. This little bit of preventative maintenance can save you lots of headaches and downtime in your server room.</p>
<p>Leave us a comment if you&#8217;ve ever seen a pump this nasty, or if you have other condensate pump stories to share.</p>
<div id="wp_thumbie" style= "border: 0pt none ; margin: 0pt; padding: 0pt; clear: both;"><div id="wp_thumbie_rl1"><h3>Related Products:</h3></div><ul class="wp_thumbie_ul_list" style="list-style-type: none; clear:both; height:190px"><li id="wp_thumbie_li" style="height:4px; width:190px; float:left; border:none"><div id="wp_thumbie_image"><a href="http://www.servercool.com/blog/spot-coolers/spot-cooling/" target="_top"><img id="wp_thumbie_thumb" src="http://www.servercool.com/wp-content/plugins/wp-thumbie/timthumb.php?src=/wp-content/uploads/2011/09/classic-plus-26.jpg&w=200&h=300&zc=1"/></a></div><div id="wp_thumbie_title"><a href="http://www.servercool.com/blog/spot-coolers/spot-cooling/" target="_top">Spot Cooling</a></div><p id="description"></p></li><li id="wp_thumbie_li" style="height:4px; width:190px; float:left; border:none"><div id="wp_thumbie_image"><a href="http://www.servercool.com/spot-cooler-sizing/" target="_top"><img id="wp_thumbie_thumb" src="http://www.servercool.com/wp-content/plugins/wp-thumbie/timthumb.php?src=/wp-content/uploads/2011/08/movincool-spot-cooler-sizing.jpg&w=200&h=300&zc=1"/></a></div><div id="wp_thumbie_title"><a href="http://www.servercool.com/spot-cooler-sizing/" target="_top">Spot Cooler Sizing</a></div><p id="description"></p></li><li id="wp_thumbie_li" style="height:4px; width:190px; float:left; border:none"><div id="wp_thumbie_image"><a href="http://www.servercool.com/uncategorized/1020/" target="_top"><img id="wp_thumbie_thumb" src="http://www.servercool.com/wp-content/plugins/wp-thumbie/timthumb.php?src=/wp-content/plugins/wp-thumbie/images/default.png&w=200&h=300&zc=1"/></a></div><div id="wp_thumbie_title"><a href="http://www.servercool.com/uncategorized/1020/" target="_top"></a></div><p id="description"></p></li></ul><div id="wp_thumbie_rl2"><small>By </small><a href="http://www.blogsdna.com"><small>Blogsdna</small></a></div></div><div class="clear"></div>]]></content:encoded>
			<wfw:commentRss>http://www.servercool.com/blog/condensate-pumps/how-to-clean-a-condensate-pump-for-spot-coolers/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Portable AC Units &#124; Spot Coolers</title>
		<link>http://www.servercool.com/blog/portable-ac-units-spot-coolers/</link>
		<comments>http://www.servercool.com/blog/portable-ac-units-spot-coolers/#comments</comments>
		<pubDate>Fri, 15 Jul 2011 05:44:03 +0000</pubDate>
		<dc:creator>Bruce</dc:creator>
				<category><![CDATA[Blog]]></category>

		<guid isPermaLink="false">http://www.servercool.com/test/?p=1002</guid>
		<description><![CDATA[Server Room Cooling Part of every company&#8217;s disaster recovery plan should include a plan for emergency cooling systems in the event of a shutdown to facility air conditioning. One of the main causes of server failure is from overheating, so keeping server room cooling at the optimum temperature is crucial for peak performance. ServerCOOL provides spot cooler [...]]]></description>
			<content:encoded><![CDATA[<p><strong>Server Room Cooling </strong><br />
Part of every company&#8217;s disaster recovery plan should include a plan for emergency cooling systems in the event of a shutdown to facility air conditioning. One of the main causes of server failure is from overheating, so keeping <a href="http://www.servercool.com/portable-ac-units.htm">server room cooling</a> at the optimum temperature is crucial for peak performance.</p>
<p>ServerCOOL provides <a href="http://www.servercool.com/spot-cooler-rentals.htm">spot cooler rentals</a> and supplemental cooling for server rooms that require <a href="http://www.servercool.com/server_rack_cooling.htm">server rack cooling</a>.</p>
<p><strong>Planned Facility Shutdowns and Maintenance Cooling </strong><br />
ServerCOOL also specializes in providing temporary cooling for your facility while you perform necessary periodic maintenance on your existing water chillers or cooling towers.</p>
<p><strong>Emergency Cooling &amp; Portable AC Rentals </strong><br />
ServerCOOL can dispatch portable air conditioners for emergencies any time of the day or night, responding on a 24/7 basis. We provide<a href="http://www.servercool.com/portable-ac-rentals.htm">portable AC rentals</a> on a moments notice, and can have you back in business in a hurry. Portable AC rentals can be on a weekly, monthy or long-term basis.</p>
<p><strong>Temporary Cooling</strong><br />
Whether your temporary cooling requirement is for a week or several months, we will provide equipment, accessories, and labor for your project.</p>
<p><strong>After Hours Cooling</strong><br />
We can provide portable air conditioning systems for supplemental cooling in times when your office building shuts the cooling systems off after normal business hours. Having supplemental cooling systems in place will keep your servers cool and will keep after hour employess comfortable.</p>
<div id="wp_thumbie" style= "border: 0pt none ; margin: 0pt; padding: 0pt; clear: both;"><div id="wp_thumbie_rl1"><h3>Related Products:</h3></div><ul class="wp_thumbie_ul_list" style="list-style-type: none; clear:both; height:190px"><li id="wp_thumbie_li" style="height:4px; width:190px; float:left; border:none"><div id="wp_thumbie_image"><a href="http://www.servercool.com/blog/spot-coolers/spot-cooling/" target="_top"><img id="wp_thumbie_thumb" src="http://www.servercool.com/wp-content/plugins/wp-thumbie/timthumb.php?src=/wp-content/uploads/2011/09/classic-plus-26.jpg&w=200&h=300&zc=1"/></a></div><div id="wp_thumbie_title"><a href="http://www.servercool.com/blog/spot-coolers/spot-cooling/" target="_top">Spot Cooling</a></div><p id="description"></p></li><li id="wp_thumbie_li" style="height:4px; width:190px; float:left; border:none"><div id="wp_thumbie_image"><a href="http://www.servercool.com/portable-ac-rentals-spot-cooler-rentals-emergency-ac-rentals/" target="_top"><img id="wp_thumbie_thumb" src="http://www.servercool.com/wp-content/plugins/wp-thumbie/timthumb.php?src=/wp-content/uploads/2011/07/map3.jpg&w=200&h=300&zc=1"/></a></div><div id="wp_thumbie_title"><a href="http://www.servercool.com/portable-ac-rentals-spot-cooler-rentals-emergency-ac-rentals/" target="_top">Portable AC Rentals - Spot Cooler Rentals - Emergency AC Rentals</a></div><p id="description"></p></li><li id="wp_thumbie_li" style="height:4px; width:190px; float:left; border:none"><div id="wp_thumbie_image"><a href="http://www.servercool.com/uncategorized/501/" target="_top"><img id="wp_thumbie_thumb" src="http://www.servercool.com/wp-content/plugins/wp-thumbie/timthumb.php?src=/wp-content/plugins/wp-thumbie/images/default.png&w=200&h=300&zc=1"/></a></div><div id="wp_thumbie_title"><a href="http://www.servercool.com/uncategorized/501/" target="_top"></a></div><p id="description"></p></li></ul><div id="wp_thumbie_rl2"><small>By </small><a href="http://www.blogsdna.com"><small>Blogsdna</small></a></div></div><div class="clear"></div>]]></content:encoded>
			<wfw:commentRss>http://www.servercool.com/blog/portable-ac-units-spot-coolers/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
<!-- This Quick Cache file was built for (  www.servercool.com/feed/ ) in 1.86013 seconds, on Feb 23rd, 2012 at 7:26 am UTC. -->
<!-- This Quick Cache file will automatically expire ( and be re-built automatically ) on Feb 23rd, 2012 at 8:26 am UTC -->
